info@picotest.com
1-877-914-7426

B-LFT 100 Low-Frequency Injection Transformer

Model: P0005773

Price: $780.00

KEY FEATURES:

  • Optimized for low frequency injection
  • Extremely low cutoff frequency
  • Low insertion loss
  • 600V CAT II isolated output
SOME TECHNICAL DATA:
  • Usable frequency range: < 100 kHz
  • -3 dB frequency: typ. << 1 Hz - 30 kHz
  • Insertion loss : typ. < 1 dB
  • Turns ratio: 1:1

Download the injection transformer manual for more information on the B-LFT 100:

B-WIT-B-LFT-User-Manual
(1.15 MB) Injection Transformer User Manual

What's included:
B-LFT 100 Injection Transformer
BNC to 4 mm banana adapter
1 Year Warranty

Model Description Price  
P0005773 B-LFT 100 Low-Frequency Injection Transformer $780.00 Add to Cart

Sometimes you need more signal level at low frequencies

B-LFT 100 is especially designed to inject low frequency signals into slow control loops such as PFC regulators. To ensure maximum signal/noise in your measurements, the B-LFT 100 is capable of injecting a 1 Hz signal at the full 2 Vrms output power of Bode 100 without saturating. For your safety, B-LFT 100 features a safely isolated (600V CAT II) output.

Specifications
characteristic Rating
Usable frequency range 1 Hz – 100 kHz
Upper -3 dB frequency5 30 kHz (typ.)
Insertion loss6
Pri-Sec Isolation voltage 600 V CAT II
Pri-Sec capacitance 600 pF @ 1kHz (typ.)
Saturation flux 0.456 Vs (typ.)
DC saturation current 0.8 mA (typ.)

Absolute maximum ratings (device will be destroyed)
characteristic Rating
Absolute max current 0.1 A
Maximum AC voltage 10 VRMS

Environmental conditions
characteristic Rating
Operating temperature -20 °C … +60 °C / -4 °F … +140 °F
Relative humidity 5 % … 80 %
Maximum altitude 2,000 m / 6,561 ft

Mechanical data
characteristic Rating
Dimensions (with connectors) 183 mm x 122 mm x 61 mm
7.2 inch x 4.8 inch x 2.4 inch
Weight 1.33 kg / 2.93 lbs

5 Input to output transfer function with 1 kO secondary resistance and 0 dBm signal source level
6 Measured at 100 Hz

Caution: To avoid equipment damage and/or severe injuries or death ensure that the absolute maximum ratings are observed and not exceeded at all times.

Copyright © 2022 Picotest. All rights reserved.